A 210 km long three-phase transmission line is operated on a 60 Hz network. Line Finally a 40 MVA power with 0.78 back power factor under 120 kv voltage is being shot. The conductor resistance value of the line is 0.10 0 / km, the inductance value Since 1.30 mH / km and capacitance value is 0.001 µF / km, Medium Transmission Line establishing the equivalent circuit model; a) -Calculate the line current and voltage of the sending side. b) Calculate the power loss on the line. c) Calculate the% voltage regulation value of the line.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
A 210 km long three-phase transmission line is operated on a 60 Hz network. Line
Finally a 40 MVA power with 0.78 back power factor under 120 kV voltage
is being shot. The conductor resistance value of the line is 0.10 0/ km, the inductance value
Since 1.30 mH / km and capacitance value is 0.001 µF / km, Medium Transmission Line
establishing the equivalent circuit model;
a) -Calculate the line current and voltage of the sending side.
b) Calculate the power loss on the line.
c) Calculate the% voltage regulation value of the line.
Transcribed Image Text:A 210 km long three-phase transmission line is operated on a 60 Hz network. Line Finally a 40 MVA power with 0.78 back power factor under 120 kV voltage is being shot. The conductor resistance value of the line is 0.10 0/ km, the inductance value Since 1.30 mH / km and capacitance value is 0.001 µF / km, Medium Transmission Line establishing the equivalent circuit model; a) -Calculate the line current and voltage of the sending side. b) Calculate the power loss on the line. c) Calculate the% voltage regulation value of the line.
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Transmission line parameter
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,