A 4-inch insulated arctic pipe is used for a construction camp. The lake source is 1500 meters away. The line is above ground on mud sills. Calculate the heat loss from the pipe if the outside ambient temperature is -40 deg F (minus 40). and the water coming out of the lake is at 1 deg C. Assume that the ID is 4-inches, OD is 4.5- inches and it s covered by 2-inches of urethane insulation. Use a k-factor of 34.9 BTU/hr-ft-degF for the pipe, 0.16 BTU-in/hr-ft2-degF for insulation, and an inside and outside convective film coefficients of 12.3 BTU/hr- ft2-deg F and 6.2 BTU/hr-ft2-deg F. Answer C 13.7 kW E 18.5 kW C 25.0kW C 28.5kW

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter5: Analysis Of Convection Heat Transfer
Section: Chapter Questions
Problem 5.3DP
icon
Related questions
Question
A 4-inch insulated arctic pipe is used for a construction camp. The lake source is 1500 meters away. The line is
above ground on mud sills. Calculate the heat loss from the pipe if the outside ambient temperature is -40 deg
F (minus 40). and the water coming out of the lake is at 1 deg C. Assume that the ID is 4-inches, OD is 4.5-
inches and it s covered by 2-inches of urethane insulation. Use a k-factor of 34.9 BTU/hr-ft-degF for the pipe,
0.16 BTU-in/hr-ft2-degF for insulation, and an inside and outside convective film coefficients of 12.3 BTU/hr-
ft2-deg F and 6.2 BTU/hr-ft2-deg F.
Answer
C 13.7 kW
C 18.5 kW
C 25.0kW
C 28.5kW
Transcribed Image Text:A 4-inch insulated arctic pipe is used for a construction camp. The lake source is 1500 meters away. The line is above ground on mud sills. Calculate the heat loss from the pipe if the outside ambient temperature is -40 deg F (minus 40). and the water coming out of the lake is at 1 deg C. Assume that the ID is 4-inches, OD is 4.5- inches and it s covered by 2-inches of urethane insulation. Use a k-factor of 34.9 BTU/hr-ft-degF for the pipe, 0.16 BTU-in/hr-ft2-degF for insulation, and an inside and outside convective film coefficients of 12.3 BTU/hr- ft2-deg F and 6.2 BTU/hr-ft2-deg F. Answer C 13.7 kW C 18.5 kW C 25.0kW C 28.5kW
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Convection
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning