A large power plant generates electricity at 12.0 kV. Its old transformer once converted the voltage to 315 kV. The secondary coil of this transformer is being replaced so that its output can be 725 kV for more efficient cross-country transmission on upgraded transmission lines. V1 = 315 kV V2 = 725 kV What is the ratio of turns in the new secondary to the number of turns in the old secondary? What is the ratio of new current output to the old current output for the same power input to the transformer? If the upgraded transmission lines have the same resistance as the original ones, what is the ratio of new line power loss to the old?
A large power plant generates electricity at 12.0 kV. Its old transformer once converted the voltage to 315 kV. The secondary coil of this transformer is being replaced so that its output can be 725 kV for more efficient cross-country transmission on upgraded transmission lines. V1 = 315 kV V2 = 725 kV What is the ratio of turns in the new secondary to the number of turns in the old secondary? What is the ratio of new current output to the old current output for the same power input to the transformer? If the upgraded transmission lines have the same resistance as the original ones, what is the ratio of new line power loss to the old?
College Physics
1st Edition
ISBN:9781938168000
Author:Paul Peter Urone, Roger Hinrichs
Publisher:Paul Peter Urone, Roger Hinrichs
Chapter20: Electric Current, Resistance, And Ohm's Law
Section: Chapter Questions
Problem 69PE: Unreasonable Results (a) What current is needed to transmit 1.00 102MW of power at 480 V? (b) What...
Related questions
Question
A large power plant generates electricity at 12.0 kV. Its old transformer once converted the voltage to 315 kV. The secondary coil of this transformer is being replaced so that its output can be 725 kV for more efficient cross-country transmission on upgraded transmission lines.
V1 = 315 kV
V2 = 725 kV
What is the ratio of turns in the new secondary to the number of turns in the old secondary?
What is the ratio of new current output to the old current output for the same power input to the transformer?
If the upgraded transmission lines have the same resistance as the original ones, what is the ratio of new line power loss to the old?
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 4 steps with 4 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, physics and related others by exploring similar questions and additional content below.Recommended textbooks for you
College Physics
Physics
ISBN:
9781938168000
Author:
Paul Peter Urone, Roger Hinrichs
Publisher:
OpenStax College
College Physics
Physics
ISBN:
9781938168000
Author:
Paul Peter Urone, Roger Hinrichs
Publisher:
OpenStax College