A refrigeration system is being designed to maintain a small frozen storage room at -5°C. The required cooling rate is 50 kW. Waste heat from the refrigeration system will be rejected to the outdoor air at 35°C. The system will be designed such that the evaporation temperature will be either -10°C or -20°C, and the condensing temperature will be either 40°C or 50°C. UAcond For the 4 possible combinations of evaporator and condenser Tcond temperatures: Apply the "rule of thumb" to estimate the cooling COP Tr Ecomp Estimate the required "size" of the evaporator heat exchange surface, UAevap Practical Refrig (W/°C) T. Estimate the required "size" of the condenser heat exchange surface, UA cond (W/°C) Tevap UAevap Show your work for Scenario A and complete the following table: Design Scenario Tevap (°C) Tcond (°C) СОР. UA evap (W/°C) UA cond (W/°C) А -10 40 В -20 40 -10 50 D -20 50
A refrigeration system is being designed to maintain a small frozen storage room at -5°C. The required cooling rate is 50 kW. Waste heat from the refrigeration system will be rejected to the outdoor air at 35°C. The system will be designed such that the evaporation temperature will be either -10°C or -20°C, and the condensing temperature will be either 40°C or 50°C. UAcond For the 4 possible combinations of evaporator and condenser Tcond temperatures: Apply the "rule of thumb" to estimate the cooling COP Tr Ecomp Estimate the required "size" of the evaporator heat exchange surface, UAevap Practical Refrig (W/°C) T. Estimate the required "size" of the condenser heat exchange surface, UA cond (W/°C) Tevap UAevap Show your work for Scenario A and complete the following table: Design Scenario Tevap (°C) Tcond (°C) СОР. UA evap (W/°C) UA cond (W/°C) А -10 40 В -20 40 -10 50 D -20 50
Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter47: High-pressure, Low-pressure, And Absorption Chilled-water Systems
Section: Chapter Questions
Problem 13RQ: The subcooling temperature in a condenser can be measured by taking the difference between the A....
Related questions
Concept explainers
Heat Exchangers
Heat exchangers are the types of equipment that are primarily employed to transfer the thermal energy from one fluid to another, provided that one of the fluids should be at a higher thermal energy content than the other fluid.
Heat Exchanger
The heat exchanger is a combination of two words ''Heat'' and ''Exchanger''. It is a mechanical device that is used to exchange heat energy between two fluids.
Question
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 5 steps with 1 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning