A space to be air-conditioned has a sensible heat load of 34.9 hp and a latent heat load of 6.97 hp. The space is to maintained at 24°C DB and 17°C WB. Outside air is at 32°C DB and 24°C WB temperatures. With a re-heater to satisfy the space conditions, the conditioned air will enter the space at 18°C. If 40% of the supply air, is fresh air and the rest is re-circulated, find the volume flow rate of space air in m3/s. The mass flow rate of supply air, ms is 312 kg/min. Take the mass flow rate of supply air, (ms = the sum of air mass flow rate to dissipate the sensible heat, msh, and the air mass flow rate to dissipate the latent heat, mlh). Take cp of dry air = unity.

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter44: Geothermal Heat Pumps
Section: Chapter Questions
Problem 13RQ: If 14 gpm of water is flowing through an open-loop heat pump with a temperature difference of 7F,...
icon
Related questions
Question

I need neat and clean handwritten solution explaining every steps. Best of luck

Question 7
A space to be air-conditioned has a sensible heat load of 34.9 hp and a latent heat load of 6.97 hp. The space is to maintained at
24°C DB and 17°C WB. Outside air is at 32°C DB and 24°C WB temperatures. With a re-heater to satisfy the space conditions, the
conditioned air will enter the space at 18°C. If 40% of the supply air, is fresh air and the rest is re-circulated, find the volume flow
rate of space air in m3/s. The mass flow rate of supply air, ms is 312 kg/min. Take the mass flow rate of supply air, (ms = the sum of
air mass flow rate to dissipate the sensible heat, msh, and the air mass flow rate to dissipate the latent heat, mlh). Take cp of dry air
= unity.
(A) 5.62
(B) 3.62
(C) 4.34
(D) 4.46
Transcribed Image Text:Question 7 A space to be air-conditioned has a sensible heat load of 34.9 hp and a latent heat load of 6.97 hp. The space is to maintained at 24°C DB and 17°C WB. Outside air is at 32°C DB and 24°C WB temperatures. With a re-heater to satisfy the space conditions, the conditioned air will enter the space at 18°C. If 40% of the supply air, is fresh air and the rest is re-circulated, find the volume flow rate of space air in m3/s. The mass flow rate of supply air, ms is 312 kg/min. Take the mass flow rate of supply air, (ms = the sum of air mass flow rate to dissipate the sensible heat, msh, and the air mass flow rate to dissipate the latent heat, mlh). Take cp of dry air = unity. (A) 5.62 (B) 3.62 (C) 4.34 (D) 4.46
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Dimensional Analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning