A- The PV array installed on the roof of a certain building has a rated power (Pmp-STC) of 600 kWp under standard test conditions. 1- Describe how to connect the SUNCECO PV modules that have 305 W, 37.24 Vmpp to construct this array if each ON-Grid inverter used to connect the PV system to the grid has a rating of P kW where P value is the last two digits (from right) of your registration number (i.e. for the student that has a registration number 202112396, P =96). The DC voltage rating at the inverter input is in the range 90 – 550 V if its rating is less than 10 kW, whereas it is in the range 450- 800 V if its rating is more than 10 kW. You have to calculate the number of series panels in each string and number of parallel strings. Draw an overall diagram for this on-grid PV system with all the protection equipment at both DC and AC side. The inverter has dual MPPTS with a rating of 10 A each. You have to include all of the analysis required to finalize your design. You may need to let number of PV modules not connected. 2- Find the real power generation of this PV array at 900 W/m² and 30 °C if the power temperature coefficient of the PV modules is -0.0045 per degree.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
P=99kw
01
A- The PV array installed on the roof of a certain building has a rated power (Pmp-STC)
of 600 kWp under standard test conditions.
1- Describe how to connect the SUNCECO PV modules that have 305 W, 37.24
Vmpp to construct this array if each ON-Grid inverter used to connect the PV
system to the grid has a rating of P kW where P value is the last two digits (from
right) of your registration number (i.e. for the student that has a registration
number 202112396, P =96). The DC voltage rating at the inverter input is in the
range 90 – 550 V if its rating is less than 10 kW, whereas it is in the range 450-
800 V if its rating is more than 10 kW. You have to calculate the number of series
panels in each string and number of parallel strings. Draw an overall diagram for
this on-grid PV system with all the protection equipment at both DC and AC side.
The inverter has dual MPPTS with a rating of 10 A each.
You have to include all of the analysis required to finalize your design. You may
need to let number of PV modules not connected.
2- Find the real power generation of this PV array at 900 W/m² and 30 °C if the
power temperature coefficient of the PV modules is -0.0045 per degree.
Transcribed Image Text:01 A- The PV array installed on the roof of a certain building has a rated power (Pmp-STC) of 600 kWp under standard test conditions. 1- Describe how to connect the SUNCECO PV modules that have 305 W, 37.24 Vmpp to construct this array if each ON-Grid inverter used to connect the PV system to the grid has a rating of P kW where P value is the last two digits (from right) of your registration number (i.e. for the student that has a registration number 202112396, P =96). The DC voltage rating at the inverter input is in the range 90 – 550 V if its rating is less than 10 kW, whereas it is in the range 450- 800 V if its rating is more than 10 kW. You have to calculate the number of series panels in each string and number of parallel strings. Draw an overall diagram for this on-grid PV system with all the protection equipment at both DC and AC side. The inverter has dual MPPTS with a rating of 10 A each. You have to include all of the analysis required to finalize your design. You may need to let number of PV modules not connected. 2- Find the real power generation of this PV array at 900 W/m² and 30 °C if the power temperature coefficient of the PV modules is -0.0045 per degree.
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Star delta conversion
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,