an abc-sequence set of voltages and Van = 120/40° V rms. If the a-phase line current and line impedance are known to be 6/15° A rms and 1 + j1 , respectively, find the load impedance. 11.50 An abc-phase-sequence three-phase balanced wye-con- nected source supplies a balanced delta-connected load. The impedance per phase in the delta load is 12 + j6 N. The line voltage at the source is Vab= 120 √3/40° V rms. If the line impedance is zero, find the line currents in the balanced wye-delta system. 11.51 An abc-phase-sequence three-phase balanced wye-connect- ed source supplies power to a balanced delta-connected load. The impedance per phase in the load is 14 + j7 . If the source voltage for the a phase is Va = 120/80° V rms and the line impedance is zero, find the phase currents in the wye-connected source. an 11.52 In a three-phase balanced delta-delta system, the source has an abc-phase sequence. The line and load impedances are 0.3 + j0.2 2 and 9 + j6 , respectively. If the load current in the delta is IAB = 15/40° A rms, find the phase bare voltages of the source. 11.53 An abc-phase-sequence three-phase balanced wye- connected source supplies a balanced delta-connected load. The impedance per phase of the delta load is 10 + j8 0. If the line impedance is zero and the line current in the a phase is known to be IA 28.10/-28.66° A rms, find the load voltage VAB = 11.54 In a balanced three-phase wye-delta system, the source has an abc-phase sequence and Van = 120/0° V rms. If the line impedance is zero and the line current IaA = 5/20° A rms, find the load impedance per phase in the delta. 11.55 A three-phase load impedance consists of a balanced wye in parallel with a balanced delta. What is the equivalent wye load and what is the equivalent delta load if the phase impedances of the wye and delta are 6 + j3 2 and 15+j10 , respectively? 11.56 In a balanced three-phase system, the source is a balanced wye with an abc-phase sequence and V ab 215/50° V rms. The load is a balanced wye in parallel with a balanced delta The phase impedance of the wye is 5 + by the 11.59 Calcul- phase the loa 11.60 A thre supply has a to tw is pu ance 11.61 Dete each 11.62 A d sequ imp loa vol and the po 11.63 A lo is 20 11.64 I S 1 11.65 C 11.66

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.43P: A three-phase line, which has an impedance of (2+j4) per phase, feeds two balanced three-phase loads...
icon
Related questions
Question
I need help with question 11.54
an abc-sequence set of voltages and Van = 120/40° V rms.
If the a-phase line current and line impedance are known
to be 6/15° A rms and 1 + j1 2, respectively, find the load
impedance.
11.50 An abc-phase-sequence three-phase balanced wye-con-
nected source supplies a balanced delta-connected load.
The impedance per phase in the delta load is 12 + j6 N.
The line voltage at the source is Vah= 120 √3/40° V rms.
If the line impedance is zero, find the line currents in the
balanced wye-delta system.
11.51 An abc-phase-sequence three-phase balanced wye-connect-
ed source supplies power to a balanced delta-connected
load. The impedance per phase in the load is 14 + j7 N. If
the source voltage for the a phase is Va
120/80° V rms
and the line impedance is zero, find the phase currents in
the wye-connected source.
an
=
11.52 In a three-phase balanced delta-delta system, the source
has an abc-phase sequence. The line and load impedances
are 0.3 + j0.2 2 and 9 + j6 , respectively. If the load
current in the delta is IAB = 15/40° A rms, find the phase
barvoltages of the source.
11.53 An abc-phase-sequence three-phase balanced wye-
connected source supplies a balanced delta-connected load.
The impedance per phase of the delta load is 10 + j8 N.
If the line impedance is zero and the line current in the a
phase is known to be IA 28.10/-28.66° A rms, find the
load voltage VAB
=
11.54 In a balanced three-phase wye-delta system, the source has
an abc-phase sequence and Van = 120/0° V rms. If the line
impedance is zero and the line current IaA = 5/20° A rms,
find the load impedance per phase in the delta.
11.55 A three-phase load impedance consists of a balanced wye
in parallel with a balanced delta. What is the equivalent
wye load and what is the equivalent delta load if the phase
impedances of the wye and delta are 6 + j3 2 and
15+j10 2, respectively?
11.56 In a balanced three-phase system, the source is a
balanced wye with an abc-phase sequence and V ab
215/50° V rms. The load is a balanced wye in parallel with
a balanced delta The phase impedance of the wye is 5 +
by the
11.59 Calcul-
phase
the loa
11.60 A thre
suppl
has a
to tw
is pu
ance
11.61 Dete
each
11.62 A d
sequ
imp
loa
vol
and
the
po
11.63 A
lo
is
20
11.64 I
S
1
11.65
C
11.66
Transcribed Image Text:an abc-sequence set of voltages and Van = 120/40° V rms. If the a-phase line current and line impedance are known to be 6/15° A rms and 1 + j1 2, respectively, find the load impedance. 11.50 An abc-phase-sequence three-phase balanced wye-con- nected source supplies a balanced delta-connected load. The impedance per phase in the delta load is 12 + j6 N. The line voltage at the source is Vah= 120 √3/40° V rms. If the line impedance is zero, find the line currents in the balanced wye-delta system. 11.51 An abc-phase-sequence three-phase balanced wye-connect- ed source supplies power to a balanced delta-connected load. The impedance per phase in the load is 14 + j7 N. If the source voltage for the a phase is Va 120/80° V rms and the line impedance is zero, find the phase currents in the wye-connected source. an = 11.52 In a three-phase balanced delta-delta system, the source has an abc-phase sequence. The line and load impedances are 0.3 + j0.2 2 and 9 + j6 , respectively. If the load current in the delta is IAB = 15/40° A rms, find the phase barvoltages of the source. 11.53 An abc-phase-sequence three-phase balanced wye- connected source supplies a balanced delta-connected load. The impedance per phase of the delta load is 10 + j8 N. If the line impedance is zero and the line current in the a phase is known to be IA 28.10/-28.66° A rms, find the load voltage VAB = 11.54 In a balanced three-phase wye-delta system, the source has an abc-phase sequence and Van = 120/0° V rms. If the line impedance is zero and the line current IaA = 5/20° A rms, find the load impedance per phase in the delta. 11.55 A three-phase load impedance consists of a balanced wye in parallel with a balanced delta. What is the equivalent wye load and what is the equivalent delta load if the phase impedances of the wye and delta are 6 + j3 2 and 15+j10 2, respectively? 11.56 In a balanced three-phase system, the source is a balanced wye with an abc-phase sequence and V ab 215/50° V rms. The load is a balanced wye in parallel with a balanced delta The phase impedance of the wye is 5 + by the 11.59 Calcul- phase the loa 11.60 A thre suppl has a to tw is pu ance 11.61 Dete each 11.62 A d sequ imp loa vol and the po 11.63 A lo is 20 11.64 I S 1 11.65 C 11.66
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Analysis of Single Phase and Three Phase System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning