An emergency power supply is required to provide a three-phase sinusoi- dal voltage source of 208 V (L-L) at a frequency of 400 Hz. The power is to be obtained from a battery consisting of cells in series, each cell hav- ing an internal voltage of 2.2 V and an internal resistance of 0.006 m. The load on the three-phase, 400-Hz system requires a fundamental fre- quency apparent power of 7.2 kVA at 0.9 power factor lagging. The in- luctance of the load is such that harmonic currents are negligible. How many cells should be connected in series to provide the required output? The switches may be regarded as ideal.

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter18: Resistive-inductive Parallel Circuits
Section: Chapter Questions
Problem 1PA: Incandescent lighting of 500 W is connected in parallel with an inductive load. A clamp-on ammeter...
icon
Related questions
Question
An emergency power supply is required to provide a three-phase sinusoi-
dal voltage source of 208 V (L-L) at a frequency of 400 Hz. The power is
to be obtained from a battery consisting of cells in series, each cell hav-
ing an internal voltage of 2.2 V and an internal resistance of 0.006 m.
The load on the three-phase, 400-Hz system requires a fundamental fre-
quency apparent power of 7.2 kVA at 0.9 power factor lagging. The in-
ductance of the load is such that harmonic currents are negligible. How
many cells should be connected in series to provide the required output?
The switches may be regarded as ideal.
Transcribed Image Text:An emergency power supply is required to provide a three-phase sinusoi- dal voltage source of 208 V (L-L) at a frequency of 400 Hz. The power is to be obtained from a battery consisting of cells in series, each cell hav- ing an internal voltage of 2.2 V and an internal resistance of 0.006 m. The load on the three-phase, 400-Hz system requires a fundamental fre- quency apparent power of 7.2 kVA at 0.9 power factor lagging. The in- ductance of the load is such that harmonic currents are negligible. How many cells should be connected in series to provide the required output? The switches may be regarded as ideal.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 6 steps with 7 images

Blurred answer
Knowledge Booster
Alternating Current (AC) Series Motor and Universal Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning