Multiple choice questions: 1- A voltages of 50Hz transformer are 1500 V on primary and 600 V on the secondary. It has 1.5 V per turn. Then the number of turns on primary and secondary are a) 20 and 8 b) 100 and 10 c) 1000 and 120 d)1000 and 400 e) none of the previous. 2-A 600/200 V single phase transformer is supplying a load of 60 A at a p.f of 0.707 lag. The no load current is 3A at 0.2 P.f. lag. Then the primary current is a) 63A b) 22.56A c) 69A d)24 e) 21.55 f) none of the previous. 3- The silicon ratio in transformer iron cannot be increased greater than 5% because of a) the iron loss will increase b) the hysteresis loss will increase c) the eddy current loss will increase d) none of the previous ICVI =400Y and the wattmeter read 800W at no load test then the value of Ro is

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.26P: A bank of three single-phase transformers, each rated 30MVA,38.1/3.81kV, are connected in Y- with a...
icon
Related questions
Question
Multiple choice questions:
1- A voltages of 50Hz transformer are 1500 V on primary and 600 V on the secondary. It
has 1.5 V per turn. Then the number of turns on primary and secondary are
a) 20 and 8 b) 100 and 10 c) 1000 and 120 d)1000 and 400 e) none of the previous.
2-A 600/200 V single phase transformer is supplying a load of 60 A at a p.f of 0.707 lag.
The no load current is 3A at 0.2 P.f. lag. Then the primary current is
a) 63A b) 22.56A c) 69A d)24 e) 21.55 f) none of the previous.
3- The silicon ratio in transformer iron cannot be increased greater than 5% because of ---
a) the iron loss will increase b) the hysteresis loss will increase c) the eddy current loss
will increase d) none of the previous
4- If VI 400V and the wattmeter read 800W at no load test then the value of Ro is-
a)100 b)40052 c) 200 d)160002 e) none of the previous
Transcribed Image Text:Multiple choice questions: 1- A voltages of 50Hz transformer are 1500 V on primary and 600 V on the secondary. It has 1.5 V per turn. Then the number of turns on primary and secondary are a) 20 and 8 b) 100 and 10 c) 1000 and 120 d)1000 and 400 e) none of the previous. 2-A 600/200 V single phase transformer is supplying a load of 60 A at a p.f of 0.707 lag. The no load current is 3A at 0.2 P.f. lag. Then the primary current is a) 63A b) 22.56A c) 69A d)24 e) 21.55 f) none of the previous. 3- The silicon ratio in transformer iron cannot be increased greater than 5% because of --- a) the iron loss will increase b) the hysteresis loss will increase c) the eddy current loss will increase d) none of the previous 4- If VI 400V and the wattmeter read 800W at no load test then the value of Ro is- a)100 b)40052 c) 200 d)160002 e) none of the previous
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L