Multiple choices cont.: c. The 3M load contacts are welded shut. d. The normally open 3M contact between wire numbers 23 and 31 is hung closed.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Multiple choices cont.: c. The 3M load contacts are welded shut. d. The normally open 3M contact between wire numbers 23 and 31 is hung closed.
154
Section 2 Basic Control Circuits
43
OL
1M
3
MOTOR 1
OL 9
OL
10
11
2M
11
2M
OL
13 MOTOR 2
2M
OL
15
OL 17
16
S SM 16
17
'18 1819
19
MOTOR 3
SM
SM
20
20
21
21
CONTROL
TRANSFORMER
28
START 1
STOP
OL1
OL2
OL3
28
23
24
24
25
25
26
27
1M
24
1M
START 2
1M
29 29
23
SO
25
2M
23
29
2M
START 3
2M
23
O 31 31
32
3M
25
3M
Figure 12-14 Sequence control schematic with wire numbers. Basic control circuits
Transcribed Image Text:154 Section 2 Basic Control Circuits 43 OL 1M 3 MOTOR 1 OL 9 OL 10 11 2M 11 2M OL 13 MOTOR 2 2M OL 15 OL 17 16 S SM 16 17 '18 1819 19 MOTOR 3 SM SM 20 20 21 21 CONTROL TRANSFORMER 28 START 1 STOP OL1 OL2 OL3 28 23 24 24 25 25 26 27 1M 24 1M START 2 1M 29 29 23 SO 25 2M 23 29 2M START 3 2M 23 O 31 31 32 3M 25 3M Figure 12-14 Sequence control schematic with wire numbers. Basic control circuits
3. Assume that all three motors shown in
Figure 12-14 are running. Now assume that
the STOP button is pressed and motors #1
and #2 stop running, but motor #3 continues
to operate. WWhich of the following could cause
this problem?
a. STOP button is shorted.
b. The 2M contact between wire numbers 31
and 32 is hung closed.
Transcribed Image Text:3. Assume that all three motors shown in Figure 12-14 are running. Now assume that the STOP button is pressed and motors #1 and #2 stop running, but motor #3 continues to operate. WWhich of the following could cause this problem? a. STOP button is shorted. b. The 2M contact between wire numbers 31 and 32 is hung closed.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Methods of Wiring
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,