Q1: For the cold storage room shown in Figure 1, calculate the transmission and the product load. The room is exposed to the outside air from the top and west side. There are two conditioned spaces (24°C) from the other two sides. The outside temperature is 40°C, floor temperature is 18°C, and the room inside freezing temperature is -18°C. For the product, the mass flow rate is 1000 kg/h, Cp=1.5 kJ/(kg.K), inlet temperature is 15°C, water content is 25%, and the freezing point is -3°C. Assume the overall heat transfer coefficient for the roof, walls, and floor is 3.5 W/(m².K) and the building is medium colored.

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter6: Forced Convection Over Exterior Surfaces
Section: Chapter Questions
Problem 6.2DP
icon
Related questions
Question
I need a step by step solution please
Q1: For the cold storage room shown in Figure 1, calculate the transmission and the
product load. The room is exposed to the outside air from the top and west side.
There are two conditioned spaces (24°C) from the other two sides. The outside
temperature is 40°C, floor temperature is 18°C, and the room inside freezing
temperature is -18°C. For the product, the mass flow rate is 1000 kg/h, Cp=1.5
kJ/(kg.K), inlet temperature is 15°C, water content is 25%, and the freezing point is
-3°C. Assume the overall heat transfer coefficient for the roof, walls, and floor is 3.5
W/(m?.K) and the building is medium colored.
conditioned
space
6m
cold storage
conditioned
room
space
East
4 m
North
4 m
Figure 1
Transcribed Image Text:Q1: For the cold storage room shown in Figure 1, calculate the transmission and the product load. The room is exposed to the outside air from the top and west side. There are two conditioned spaces (24°C) from the other two sides. The outside temperature is 40°C, floor temperature is 18°C, and the room inside freezing temperature is -18°C. For the product, the mass flow rate is 1000 kg/h, Cp=1.5 kJ/(kg.K), inlet temperature is 15°C, water content is 25%, and the freezing point is -3°C. Assume the overall heat transfer coefficient for the roof, walls, and floor is 3.5 W/(m?.K) and the building is medium colored. conditioned space 6m cold storage conditioned room space East 4 m North 4 m Figure 1
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Entropy
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning