Q3 A 750 kVA, 11 kV/ 400 V with 5% impedance distribution transformer is to be installed in an industrial power network to serve the industrial motor pump as depicted in Figure Q3. (1) Analyse the short circuit capacity of the transformer (in kVA) (1) Investigate the voltage variation (in percentage) during the motor starting (i) Recommend a proper size of the transformer if the voltage variation during the motor starting is to be limited to a maximum value of 8% Infinite source Standard rating (in kVA): 150, 250, 300, 400, 500, 630, 750, 1,000, 1,250, 1,600, 2,000, 2,500 750 kVA 11kV/400V Horse Power = 500 HP MPF=0.8 lagging, Efficiency = 70% Starting inrush current = 6 times

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.28MCQ
icon
Related questions
Question
Q3
A 750 kVA, 11 kV/ 400 V with 5% impedance distribution transformer is to be
installed in an industrial power network to serve the industrial motor pump as
depicted in Figure Q3.
(1) Analyse the short circuit capacity of the transformer (in kVA)
(1) Investigate the voltage variation (in percentage) during the motor starting
(ii) Recommend a proper size of the transformer if the voltage variation during
the motor starting is to be limited to a maximum value of 8%
Infinite source
Standard rating (in kVA):
150, 250, 300, 400, 500,
630, 750, 1,000, 1,250,
1,600, 2,000, 2,500
750 KVA
11kv/ 400V
Horse Power = 500 HP
MPF=0.8 lagging, Efficiency = 70%
Starting inrush current = 6 times
Transcribed Image Text:Q3 A 750 kVA, 11 kV/ 400 V with 5% impedance distribution transformer is to be installed in an industrial power network to serve the industrial motor pump as depicted in Figure Q3. (1) Analyse the short circuit capacity of the transformer (in kVA) (1) Investigate the voltage variation (in percentage) during the motor starting (ii) Recommend a proper size of the transformer if the voltage variation during the motor starting is to be limited to a maximum value of 8% Infinite source Standard rating (in kVA): 150, 250, 300, 400, 500, 630, 750, 1,000, 1,250, 1,600, 2,000, 2,500 750 KVA 11kv/ 400V Horse Power = 500 HP MPF=0.8 lagging, Efficiency = 70% Starting inrush current = 6 times
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Y parameter
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L