QUESTION 1 A manufacturer conducted an experiment for an evaporator capacity 533 kW cooling and designed for high COP of 1.8 when using lithium bromide plus water in an absorption refrigeration system. The evaporator operates 20 C, condenser 40 C & absorber 45 C supplying 1.4 kg/s of water plus lithium bromide solution to the generator. For a condenser size of 608 kW, determine: Heat provided by the generator & absorber capacity in kW (equating overall heat balance of all heat exchanger). Show in the Solution Paper: Heat provided by the generator Provide in the Answer Box: Absorber Capacity in kW Answer in two decimal places

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter44: Geothermal Heat Pumps
Section: Chapter Questions
Problem 13RQ: If 14 gpm of water is flowing through an open-loop heat pump with a temperature difference of 7F,...
icon
Related questions
Question
QUESTION 1
A manufacturer conducted an experiment for an evaporator capacity 533 kW cooling and designed for high COP of 1.8 when using lithium bromide plus water in an absorption refrigeration system.
The evaporator operates 20 C, condenser 40 C & absorber 45 C supplying 1.4 kg/s of water plus lithium bromide solution to the generator. For a condenser size of 608 kW, determine:
Heat provided by the generator & absorber capacity in kW (equating overall heat balance of all heat exchanger).
Show in the Solution Paper: Heat provided by the generator
Provide in the Answer Box: Absorber Capacity in kW
Answer in two decimal places
Transcribed Image Text:QUESTION 1 A manufacturer conducted an experiment for an evaporator capacity 533 kW cooling and designed for high COP of 1.8 when using lithium bromide plus water in an absorption refrigeration system. The evaporator operates 20 C, condenser 40 C & absorber 45 C supplying 1.4 kg/s of water plus lithium bromide solution to the generator. For a condenser size of 608 kW, determine: Heat provided by the generator & absorber capacity in kW (equating overall heat balance of all heat exchanger). Show in the Solution Paper: Heat provided by the generator Provide in the Answer Box: Absorber Capacity in kW Answer in two decimal places
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Convection
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning