The following data were obtained from space cooling load survey of an Air-Conditioning (AC) system of a Conference Hall: Sensible Heat Load Latent heat Load 10.5 tons 2.0 tons Design inside condition is set at 22 C dry bulb temperature and 60 percent relative humidity. Cold air is supplied to the Hall at 14 °C. The AC system is designed with mass ratio of 4:1 total supplied cooled air to required minimum outdoor ventilation air. Outdoor air is 30 °C dry bulb and 70% relative humidity. Determine: a) Refrigeration capacity of the Air-Cooling Apparatus in tons

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter42: Heat Gains And Heat Losses In Structures
Section: Chapter Questions
Problem 1RQ: An oversized air-conditioning system will A. cost more to install and operate. B. be more efficient...
icon
Related questions
Question

answer letter a and plot the psychrometric chart 

The following data were obtained from space cooling load survey of an Air-Conditioning (AC)
system of a Conference Hall:
Sensible Heat Load
Latent heat Load
10.5 tons
2.0 tons
Design inside condition is set at 22 C dry bulb temperature and 60 percent relative humidity. Cold
air is supplied to the Hall at 14 °C. The AC system is designed with mass ratio of 4:1 total supplied
cooled air to required minimum outdoor ventilation air. Outdoor air is 30 °C dry bulb and 70%
relative humidity.
Determine:
a) Refrigeration capacity of the Air-Cooling Apparatus in tons
Transcribed Image Text:The following data were obtained from space cooling load survey of an Air-Conditioning (AC) system of a Conference Hall: Sensible Heat Load Latent heat Load 10.5 tons 2.0 tons Design inside condition is set at 22 C dry bulb temperature and 60 percent relative humidity. Cold air is supplied to the Hall at 14 °C. The AC system is designed with mass ratio of 4:1 total supplied cooled air to required minimum outdoor ventilation air. Outdoor air is 30 °C dry bulb and 70% relative humidity. Determine: a) Refrigeration capacity of the Air-Cooling Apparatus in tons
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning