The parameters of a 1000/250V, 50HZ single phase transformer are: R1=1.3 N, X1=2.8 N, R2=0.11 N, X2=0.2 N, R,=250 N, X,=900 N. If the load voltage is 220V, load power is 10kW, and load power factor is 0.8 lagging. Find by using the exact equivalent circuit: (i) Input current, (ii) The input voltage and power factor, (iii) The magnetizing current,
The parameters of a 1000/250V, 50HZ single phase transformer are: R1=1.3 N, X1=2.8 N, R2=0.11 N, X2=0.2 N, R,=250 N, X,=900 N. If the load voltage is 220V, load power is 10kW, and load power factor is 0.8 lagging. Find by using the exact equivalent circuit: (i) Input current, (ii) The input voltage and power factor, (iii) The magnetizing current,
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.26P: A bank of three single-phase transformers, each rated 30MVA,38.1/3.81kV, are connected in Y- with a...
Related questions
Question
100%
The parameters of a 1000/250V, 50HZ single phase transformer are: R1=1.3 N, X1=2.8 N, R2=0.11 N, X2=0.2 N, R,=250 N, X,=900 N. If the load voltage is 220V, load power is 10kW, and load power factor is 0.8 lagging. Find by using the exact equivalent circuit: (i) Input current, (ii) The input voltage and power factor, (iii) The magnetizing current, (iv) The copper losses, (v) The voltage regulation.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 5 steps with 5 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning