Example 2: The following data apply to an air-conditioning system RSH=11.6 kW RLH=11.6 Kw In side condition 25°C & RH=50% & outside condition 35°C DBT & 27.8°C WBT Return air from the room is mixed with the outside air before entering the cooling coil a ratio 4:1 Return air from the room is mixed with the air leaving the cooling coil at a ratio 1:4, cooling coil by pass factor =0.1. The air may be reheated if necessary before suppling the condition, assume tdp=10°C. find 1- Supply air condition to the room 2- Refrigeration load (Colling coil load) 3- Total refrigeration capacity d- The quantity of fresh air supplied

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter10: System Charging
Section: Chapter Questions
Problem 15RQ: A service technician is charging an air-conditioning system that has a TX V as the metering device...
icon
Related questions
Question
Example 2: The following data apply to an air-conditioning
system
RSH=11.6 kW
RLH=11.6 Kw
In side condition 25°C & RH=50% & outside condition 35°C DBT
& 27.8°C WBT
Return air from the room is mixed with the outside air before
entering the cooling coil a ratio 4:1
Return air from the room is mixed with the air leaving the
cooling coil at a ratio 1:4, cooling coil by pass factor =0.1. The
air may be reheated if necessary before suppling the condition,
assume tdp=10°C. find
1- Supply air condition to the room
2- Refrigeration load (Colling coil load)
3- Total refrigeration capacity
d- The quantity of fresh air supplied
Transcribed Image Text:Example 2: The following data apply to an air-conditioning system RSH=11.6 kW RLH=11.6 Kw In side condition 25°C & RH=50% & outside condition 35°C DBT & 27.8°C WBT Return air from the room is mixed with the outside air before entering the cooling coil a ratio 4:1 Return air from the room is mixed with the air leaving the cooling coil at a ratio 1:4, cooling coil by pass factor =0.1. The air may be reheated if necessary before suppling the condition, assume tdp=10°C. find 1- Supply air condition to the room 2- Refrigeration load (Colling coil load) 3- Total refrigeration capacity d- The quantity of fresh air supplied
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning