Practice Problem 1,2 A 60 - cycle, 150 kVA, three winding transformer is rated at 4,800 volts primary voltage, and there are two secondary windings, one rated at 720 Volts and the other at 240 Volts. There are 360 primary turns. The rating of each secondary winding is 75 kVA. Determine (a) turns in each secondary winding: (b) rated primary current at unity power factor; (c) rated primary current at 0.707 power factor lagging current; (d) rated current of the 600-Volt and 240-Volt secondaries at unity power factor. Answers: (c) I, = 31.25/-45" Amp. 104.167 /Q" Amp.; (a) NSI = 54 turnsi N = 18 turns (b) I, 31.25/0" Amp. (d) 312.5/0" Amp. %3!

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Practice Problem 1.2
A 60 - cycle, 150 kVA, three winding transformer is rated at 4,800 volts primary voltage, and
there are two secondary windings, one rated at 720 Volts and the other at 240 Volts. There are
360 primary turns. The rating of each secondary winding is 75 kVA. Determine (a) turns in each
secondary winding; (b) rated primary current at unity power factor; (c) rated primary current at
0.707 power factor lagging current; (d) rated current of the 600-Volt and 240-Volt secondaries
at unity power factor.
Answers:
(a) N. = 54 turnsi N2
= 18 turns
(c)
I, = 31.25/- 45" Amp.
SI
(b) I,
31.25/0" Amp.
(d)
= 104.167/0" Amp.i I
312.5/0" Amp.
Transcribed Image Text:Practice Problem 1.2 A 60 - cycle, 150 kVA, three winding transformer is rated at 4,800 volts primary voltage, and there are two secondary windings, one rated at 720 Volts and the other at 240 Volts. There are 360 primary turns. The rating of each secondary winding is 75 kVA. Determine (a) turns in each secondary winding; (b) rated primary current at unity power factor; (c) rated primary current at 0.707 power factor lagging current; (d) rated current of the 600-Volt and 240-Volt secondaries at unity power factor. Answers: (a) N. = 54 turnsi N2 = 18 turns (c) I, = 31.25/- 45" Amp. SI (b) I, 31.25/0" Amp. (d) = 104.167/0" Amp.i I 312.5/0" Amp.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,