To determine

The distributed parameters of RG-223/U coaxial cable at the given frequency.

Expert Solution & Answer
Check Mark

Answer to Problem 6.1P

The distributed resistance is 3.32 Ω/m , distributed inductance is 223nH/m , distributed conductance is 560×1018S/m and distributed capacitance is 112pF/m .

Explanation of Solution

Given:

The radius a of inner conductor is 0.47 mm and the outer conductor has inner radius b of 1.435 mm .The dielectric material is polyethylene and the conductor is copper. The given frequency is 800 MHz .

Concept used:

The series distributed resistance parameter R is shown below.

  R=12π(1a+1b)πfμσc   ........ (1)

Here, σc is the conductor’s conductance.

The series distributed inductance parameter L is shown below.

  L=μ2πln(ba)   ........ (2)

The shunt distributed conductance parameter G is shown below.

  G=2πσdln(ba)   ........ (3)

Here, σd is the dielectric’s conductance.

The shunt distributed capacitance parameter C is shown below.

  C=2πεln(ba)

Calculation:

The conductance σc of copper is 5.8×107S/m , conductance σd of polyethylene is 1016S/m and relative permittivity εr of polyethylene is 2.26 .

Substitute 0.47×103 for a , 1.435×103 for b , 8×108 for f , 4π×107 for μ0 and 5.8×107 for σc in equation (1).

  R=12π(1 0.47× 10 3 +1 1.435× 10 3 ) π( 8× 10 8 )( 4π× 10 7 ) 5.8× 10 7 3.32 Ω/m

Therefore, the distributed resistance parameter R is 3.32 Ω/m .

Substitute 4π×107 for μ0 , 0.47×103 for a and 1.435×103 for b in equation (2).

  L=4π× 10 72πln( 1.435× 10 3 0.47× 10 3 )=2.23×107223×109H/m

Therefore, the distributed inductance parameter L is 223nH/m .

Substitute 1016 for σd , 0.47×103 for a and 1.435×103 for b in equation (3).

  G=2π× 10 16ln( 1.435× 10 3 0.47× 10 3 )=5.62×1016560×1018S/m

Therefore, the distributed conductance parameter G is 560×1018S/m .

The distributed conductance in dielectric can be written as,

  C=2πεrε0ln(ba)

Substitute 2.26 for εr , 8.854×1012 for ε0 , 0.47×103 for a and 1.435×103 for b in above equation.

  C=2π( 2.26)( 8.854× 10 12 )ln( 1.435× 10 3 0.47× 10 3 )112×1012F/m

Therefore, the distributed capacitance parameter C is 112pF/m .

Conclusion:

Thus, the distributed resistance is 3.32 Ω/m , distributed inductance is 223nH/m , distributed conductance is 560×1018S/m and distributed capacitance is 112pF/m .

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
An ACSR conductor has a diameter of 2 cm has internal inductance of 0.05 mH/Km. If this ACSR is replaced with another having a diameter, of 4 cm then its internal inductance is?
A piece of RG-59B/U Coaxial cable has a nominal capacitance of 0.8 F/m, and 8.5 H inductance per meter. Assume the diameter of the inner conductor as 0.8m, and the dielectric constant of the insulation as 2.9. Find the diameter of the outer conductor in cm?
If reflection coefficient = 0.15 and Intrinsic impedance n₁=20.5, then n₂=? (n=3.14154 and take the decimal part at least 3 digits in the operations) Answer:

Chapter 6 Solutions

Fundamentals of Electromagnetics with Engineering Applications

Knowledge Booster
Background pattern image
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning