Chapter 2, Problem 14P
To determine
Find the external wind pressure acting on the windward and leeward side of the roof of the building.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Determine the external wind pressure on the roof of the rigid-gabled frame of a building for an essential disaster operation center shown in Fig. P2.14. The building is located in Kansas City, Missouri, where the terrain is representative of exposure C and the basic wind speed for risk category IV buildings is 120 mph. Assume the wind direction is normal to the ridge, as shown in the figure. Use Kd 50.85 for main wind-force resisting systems, and Ke =1
1)The roof of rigid gabled frames 5 meters on centers has a slope of 30 degrees. If the wind velocity pressure in the area is 3KPa , Gust Effect Factor, Gt=0.85 and external pressure coefficient of 0.35 (pressure) and 0.47 (suction). Calculate the total amount of wind load in KPa on the leeward side of the roof. Express your answer in 2 decimal places
The roof of rigid gabled frames 5 meters on centers has a slope of 30 degrees. If the wind velocity pressure in the area is 3.2KPa , Gust Effect Factor, Gt=0.85 and external pressure coefficient of 0.35 (pressure) and 0.42 (suction). Calculate the total amount of wind load in KPa on the windward side of the roof. Express your answer in 2 decimal places.
Knowledge Booster
Similar questions
- **do not solve this problem using the eqn F= Cs x W please use the example used in the textbook (image attached)** problem: A two-story hospital facility shown in Figure P2.24 is being designed in New York with a basic wind speed of 90 mph and wind exposure D. The importance factor I is 1.15 and K, = 1.0. Use the simplified procedure to determine the design wind load, base shear, and building overturning moment. (b) Use the equivalent lateral force procedure to determine the seismic base shear and overturning moment. The facility, with an average weight of 90 lb/ft? for both the floor and roof, is to be designed for the following seismic factors: Sds= 0.27 and Sd1= 0.06 reinforced concrete frames within our value of eight are to be used. The importance factor is 1.5. (C) do wind forces or seismic forces govern the strength design of the building?arrow_forwardAn eight Storey city library is proposed to be constructed in Baguio. The structure shall be a reinforced concrete building (no shear walls). The weight per floor (including 1st floor) is estimated to be 1800 KN. The roof deck weighs 1700 KN. Solve for the Base Shear, V, for the condition above using the following formulas: 1. V =ZICKSW (SEAOC CODE 1974 - 4 TH Revision) Adopted by National Structural Code of the Philippines, 3rd edition (NSCP 1987) 2. V = ZICW/Rw National Structural Code of the Philippines, 4th edition (NSCP 1992), Volume I 3. Most critical formula for V as indicated in Sec. 208.5.2 of the NSCP Vol.1 5th edition (2001). 4. Most critical formula for V as indicated in the NSCP Vol.1 6th edition (2015). 1700 KN 100 KN 32 1800 KN La Tide Toeang Warg 32 1800 KN 32 259 32 1800 KN 32 1800 KN City Cam Cena, Nagun C Bengt Nearet Active failt Trace t Fae tunao Fa Segnet Nane Tut Fat Vear Maper 2012 Ma t et 10 00 32 1800 KN 3.5 20 Floor height: 1st floor 3.5m and the rest of the…arrow_forwardUsing Method 1, what is the basic wind pressure, q, at the upper part of a 40 ft high hospital in downtown Salt Lake City, Utah? OA 13.4 pst OB 154 psf OC 181pM OD 203 patarrow_forward
- What is the effect of wind load on tall buildings? calculate wind pressure by equivalent state method at 30 cm height where the basic wind speed is 40 m/sec. At 30 m height probability factor=1.0; terrain roughness factor=1.12; topography factor=1.0; and importance factor=1.0arrow_forwardProblem- For design of a roof truss, if the design wind velocity is 20 m/s, what is the design wind pressure?arrow_forwardTo simplify the load determination, we will assume the Casper Hospital is a 210 ftx162 ft rectangle. The building, as seen in the Typical Braced Frames Showing Story Height document, is 122' 6" tall. Treat internal pressure (qi) as 0. What is the total (windward + leeward) design wind force acting on the hospital in the short direction (i.e the unit vector that is used to describe the short side of the rectangle) when the long side is the windward face? Use the ASCE 7-16 documenta to determine V, Ke, K2, Kzt, Ka, G, C, and I when doing your calculations. Table 27.2-1 in ASCE 7-16 will help guide you through the process. You may use a spread sheet to aid in your calculations as you will have many K, factors for different heights of the building. PLAN VIEW ELEVATION VIEW LEEWARD WINDWARD LEEWARD Short direction 162' 122' 6" Long direction WINDWARD 210 162'arrow_forward
- Problem 4: An advertising billboard is designed to withstand the bending moment during a peak wind speed of 35 m/s. A 1/18 scale model billboard is to be tested in a water channel. Determine (a) the dimensionless parameters, (b) the channel's water velocity to meet dynamic similarity, and (c) if the bending moment of the billboard is measured as 320 N-m in the water channel, what is the expected bending moment for the prototype during peak winds. Assume the fluid properties are as follows: P air = 1.2 kg/m³, p H20 = 1000 kg/m³, µ air = 1.80-10-5 kg/(m-s), and µ í20 = 1.14 · 10-3 kg/(m:s).arrow_forwardSituation No. 1: A 5 storey building is constructed with 15 ft. storey heights. The base shear has been calculated as 165 kips. Each story floor has weight of 700 kips. If the natural period of oscillation is 0.60 sec. Compute the shear at the 5th floor. Compute the shear force at the 4th floor 3. Compute the shear force at the 3rd floor.arrow_forwardDetermine the external wind pressure on the roof of the rigid-gabled frame of a buikding for an essential disaster operation center. The building is located in Kansas City, Missouri, where the terrain representative of exposure C and the basic wind speed for riak category IV building is 120 mph. Assume the qind dire tion is normal to the ridge, as shown in the figure. Use Kd=0.85 for main wind-force resisting system and Ke=1.arrow_forward
- Use the ASCE 7 equations for building vibration period and base shear and calculate the design base shear for the following building. Building information: Building height:Location:Function:Total building weight:Structural system: 160-ft tallSanta Monica, CA (Seismic Design Category E)Hospital (Importance factor, I =1.5)7,400 kipsSteel eccentrically braced frame (R= 8)arrow_forwardSteel floor beam (A = 9,100 mm²) - Steel girder (A = 25,600 mm?) Problem 2. The floor system of a gymnasium consists of a 130- A D Steel B mm-thick concrete slab resting on four steel beams (A = 9,100 column mm2) that, in turn, are supported by two steel girders (A = 25,600 mm2), as shown in Figure. Determine the dead loads 130 mm 10 m concrete acting on beam BF and girder AD. slab E - G - 3 at 5 m = 15 marrow_forwardProblem No. 4 A two-story apartment has interior columns that are spaced 4.5 meters apart in two perpendicular directions. If the loading on the flat roof is estimated to be 1.00 kN/m?, determine the live load supported by a typical interior column at (a) the ground-floor level, and (b) the second floor level. Hint: Use Reducible Live Load Formulaarrow_forward