Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN: 9781305387102
Author: Kreith, Frank; Manglik, Raj M.
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 2, Problem 2.58P
To determine
The temperature distribution and heat flow rate per meter length.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Derive an expression for the overall heat transfer coefficient for the following case of a flat furnace wall in the x-direction.
Let A= transfer area
Determine the total thermal resistance of a unit area of the wall section shown in Fig.
HOutside air film
Face brick, 90 mm
Air space
Sheathing, 13-mm fiberboard
Insulation, 75-mm mineral fiber
Air space
Gypsum board, 13 mm
Inside air film
A composite component is comprised of a tube and a concentric rod running inside it, both
with a length of 1.5 meters. The tube is made of copper and has inner and outer diameters
of 60 mm and 100 mm, respectively, a coefficient of thermal expansion and elastic
modulus of 17 x10-°C and 117 GPa, respectively. The rod is made of aluminium with a
diameter, coefficient of thermal expansion and elastic modulus of 50 mm, 23 ×10-6C and
80 GPa, respectively. If the composite is exposed to a temperature rise of 120°C,
determine:
1.1
The sense and magnitude of the stresses induced in the composite if it is not restrained.
The sense and magnitude of the stresses induced in the composite if it is partially restrained
1.2
with an allowed free expansion of 0.3 mm.
Chapter 2 Solutions
Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
Ch. 2 - A plane wall, 7.5 cm thick, generates heat...Ch. 2 -
2.2 A small dam, which is idealized by a large...Ch. 2 - 2.3 The shield of a nuclear reactor is idealized...Ch. 2 - A plane wall 15 cm thick has a thermal...Ch. 2 - 2.5 Derive an expression for the temperature...Ch. 2 - A plane wall of thickness 2L has internal heat...Ch. 2 - 2.7 A very thin silicon chip is bonded to a 6-mm...Ch. 2 - 2.9 In a large chemical factory, hot gases at 2273...Ch. 2 - 2.14 Calculate the rate of heat loss per foot and...Ch. 2 - 2.15 Suppose that a pipe carrying a hot fluid with...
Ch. 2 - Prob. 2.16PCh. 2 - Estimate the rate of heat loss per unit length...Ch. 2 - The rate of heat flow per unit length q/L through...Ch. 2 - A 2.5-cm-OD, 2-cm-ID copper pipe carries liquid...Ch. 2 - A cylindrical liquid oxygen (LOX) tank has a...Ch. 2 - Show that the rate of heat conduction per unit...Ch. 2 - Derive an expression for the temperature...Ch. 2 - Heat is generated uniformly in the fuel rod of a...Ch. 2 - 2.29 In a cylindrical fuel rod of a nuclear...Ch. 2 - 2.30 An electrical heater capable of generating...Ch. 2 - A hollow sphere with inner and outer radii of R1...Ch. 2 - 2.34 Show that the temperature distribution in a...Ch. 2 -
2.38 The addition of aluminum fins has been...Ch. 2 - The tip of a soldering iron consists of a 0.6-cm-...Ch. 2 - One end of a 0.3-m-long steel rod is connected to...Ch. 2 - Both ends of a 0.6-cm copper U-shaped rod are...Ch. 2 - 2.42 A circumferential fin of rectangular cross...Ch. 2 - 2.43 A turbine blade 6.3 cm long, with...Ch. 2 - 2.44 To determine the thermal conductivity of a...Ch. 2 - 2.45 Heat is transferred from water to air through...Ch. 2 - 2.46 The wall of a liquid-to-gas heat exchanger...Ch. 2 - Prob. 2.47PCh. 2 - The handle of a ladle used for pouring molten lead...Ch. 2 - 2.50 Compare the rate of heat flow from the bottom...Ch. 2 - 2.51 Determine by means of a flux plot the...Ch. 2 - Prob. 2.52PCh. 2 - Determine the rate of heat transfer per meter...Ch. 2 - Prob. 2.54PCh. 2 - 2.55 A long, 1-cm-diameter electric copper cable...Ch. 2 - Prob. 2.56PCh. 2 - Prob. 2.57PCh. 2 - Prob. 2.58P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Determine the heat flux through the composite walls as shown in Figure. The frontal area (normal to heat flow) for the layers of Fir brick and Brick is 1 sq.m. The frontal area for Asbestos and Earth layers are equal and the summation of the frontal areas of them is 1 sq.m. as shown required to answer. OPTIONS: 1.Heat flux is around 487.3 Watt 2.Heat flux is around 742.7 Watt 3.Heat flux is around 305.4 Watt 4.Nonearrow_forwardc) A steel pipe of 100 mm bore, and 10 mm bore thickness, carrying dry saturated steam at 28 bars, is insulated with a 40 mm layer of moulded insulation. This insulation in turn is insulated with a 60 mm layer of felt. The atmospheric temperature is 15 °C. Calculate: (i) the rate of heat loss by the steam per metre pipe length. (ii) the temperature of the outside Dimensions in mm surface.zzzzzzz h₂-15 W/m²K Steel k₁=50 W/mK AVALEHT Ø100 1₂ " Steam 28 bar h-550 W/m²K, Inner heat transfer coefficient = 550 W/m² K Outer heat transfer coefficient = 15 W/m² K Thermal conductivity of steel = 50 W/m K Thermal conductivity of felt = 0.07 W/m K Moulded insulation Felt Moulded insulation K₂=0.09 W/mK Thermal conductivity of moulded insulation = 0.09 W/m 40 10. A 60 15°C Felt K₁=0.07 W/mK zzzzzzzzarrow_forwardA composite component is comprised of a tube and a concentric rod running inside it, both with a length of 1.5 meters. The tube is made of copper and has inner and outer diameters of 60 mm and 100 mm, respectively, a coefficient of thermal expansion and elastic modulus of 17 x10-6C and 117 GPa, respectively. The rod is made of aluminium with a diameter, coefficient of thermal expansion and elastic modulus of 50 mm, 23 x10-6C and 80 GPa, respectively. If the composite is exposed to a temperature rise of 120°C, determine: 1.2 The sense and magnitude of the stresses induced in the composite if it is partially restrained with an allowed free expansion of 0.3 mm.arrow_forward
- A composite wall consists of alternating layers of concrete and brick (refer to figure). The convective heat transfer coefficient, h is known for the sides of the wall. Compute Q and U for the wall. Concrete (T) Ap Brick Configurationarrow_forwardQ1/ The fumace wall consists of 120 mm wide Reftactory bricks Air gap Insulating fire bricks -Plaster refractory brick and 120 mm wide insulating fire brick separated by an air gap. The outside wall is covered with a 12 mm thickness of plaster. The inner surface of the wall is at 1090°C and the - 1090°C room temperature is 20°C. The heat transfer coefficient from the outside wall surface to the air in the room is 18 W/m² °C, and the resistance to heat flow of the air gap is 0.16 °C /W. If the thermal conductivities of the refractory brick, insulating fire brick, and plaster are 1.6, 0.3 and 0.14 W/m. °C, respectively calculates: (i) Rate at which heat is lost per m of the wall surface; (ii) Each interface temperature. -20°C - 120 mm 120 mm12 mmarrow_forward1. Heat Loss from saturated steam at 121.1°C. The line is covered with 25.4 mm of insulation. Assuming that the inside surface temperature of the metal wall is at 121.1°C and the outer sur- face of the insulation is at 26.7°C, calculate the heat loss for 30.5 m of pipe. Also, calculate the kg of steam condensed per hour in the pipe due to the heat loss. The average k for steel from Appendix A.3 is 45 W/m K and the k for the insulation is 0.182. a Steam Pipeline. A steel pipeline, 2-in. Schedule 40 pipe, contains A 381 Stearrow_forward
- A composite component is comprised of a tube and a concentric rod running inside it, both with a length of 1.5 meters. The tube is made of copper and has inner and outer diameters of 60 mm and 100 mm, respectively, a coefficient of thermal expansion and elastic modulus of 17 x10-C and 117 GPa, respectively. The rod is made of aluminium with a diameter, coefficient of thermal expansion and elastic modulus of 50 mm, 23 x10-6C and 80 GPa, respectively. If the composite is exposed to a temperature rise of 120°C, determine: 1.1 The sense and magnitude of the stresses induced in the composite if it is not restrained.arrow_forwardProblem 1 A hot water pipe is used for domestic applications is insulated with a layer of calcium silicate. If the insulation is 25 mm thick and its inner and outer surfaces are maintained at Ts,1 = 800 K and Ts,2 = 400 K, respectively. The outside diameter is 0.12 m. Given the thermal conductivity calcium silicate insulation equals to 0.09 W/m.K. A. Define the difference between lagged and unlagged pipes. B. Calculate the heat loss per unit length for this pipe.arrow_forward1 example each Conductive heat flow through thick walled tube. CONDUCTED HEAT FLOW THROUGH THICK SPHEREarrow_forward
- Provide two sample question regarding Heat transfer between two fluids separated by walls of a composite tube of solid materialsarrow_forwardWrite the expression for critical radius of insulation for a cylindrical pipe. Consider aninsulated pipe exposed to the atmosphere. Will the critical radius of insulation begreater on calm days or on windy days? Why?arrow_forwardA pipe has inner diameter 31 mm, outer diameter 106 mm, and length 4.3 m. Its thermal conductivity is 476 W m-1 K-1. The inner and outer surface temperatures are 103°C and 18°C, respectively. What is the heat transfer rate from inside to outside? (Answer in W and round your answer to the nearest integer) Handwritten pleasearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning
Understanding Conduction and the Heat Equation; Author: The Efficient Engineer;https://www.youtube.com/watch?v=6jQsLAqrZGQ;License: Standard youtube license