Question
Chapter 4, Problem 4.18PFS
To determine
The selection of a pair ofC10channels for a tension member.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
2-PL10x1/2
A-36
Bolts are 7/8 in A-325,
threads are not excluded.
All edge spacings are minimum
| 3" | 3" |
о
PL 10x3/4
A-572Gr50
a) Determine the nominal bolt capacity.
b) Determine the nominal bearing capacity for each plate.
c) Determine the nominal rupture capacity of each plate.
d) What is the nominal capacity of the connection?
e) Using LRFD, is this connection capable of supporting a dead load of 150 kip and a live
load of 100 kip?
A tension connection consists of A36 steel double angles (two L4x4x1/4 shapes, or 2L4x4x1/4)
fastened to a 4x10 No. 2 Red Oak member with a single row of four 0.875 inch A307 bolts.
The connection is subjected to normal temperatures but wet in-service conditions. Assume
the group action factor is C,=0.95 and the geometry factor is Ca=1. The controlling ASD
load combination is D+ L where L is from occupancy.
Elevation
Cross Section
L4x4x1/4
L4x4x1/4
Pa
Р.
2L4x4x1/4
4х10
4x10
Plan
L4x4x1/4
Pa/2
Pa
4x10
L4x4x1/4
Pa/2
• Determine the load, Pa, that the connection can support based on tension strength of
the 4x10.
Pa=.
lb
• Determine the load, Pa, that the connection can support based on gross tension yield
of the double angles. The ASD design strength for gross tension yield is F,A,/1.67
where F=36 ksi, A,=1.93 in² for each L4x4x1/4.
Pa=.
lb
4. Determine the service load capacity of 2C10X20 channels
as a truss member attached to a 7/8 in gusset plate as shown
in Figure e5.20. The steel is A572 Grade 65 and the 7/8 in
diameter A325 bolts are in a bearing-type connection (A325-
X) with no threads in the shear planes. The load is 25% dead
load and 75% live load
O
4@3-1-0
O
C10 x 20
Chapter 4 Solutions
Structural Steel Design (6th Edition)
Ch. 4 - Prob. 4.1PFSCh. 4 - Prob. 4.2PFSCh. 4 - Prob. 4.3PFSCh. 4 - Prob. 4.4PFSCh. 4 - Prob. 4.5PFSCh. 4 - Prob. 4.6PFSCh. 4 - Prob. 4.7PFSCh. 4 - Prob. 4.8PFSCh. 4 - Prob. 4.9PFSCh. 4 - Prob. 4.10PFS
Ch. 4 - Prob. 4.11PFSCh. 4 - Prob. 4.12PFSCh. 4 - Prob. 4.13PFSCh. 4 - Prob. 4.14PFSCh. 4 - Prob. 4.15PFSCh. 4 - Prob. 4.16PFSCh. 4 - Prob. 4.17PFSCh. 4 - Prob. 4.18PFSCh. 4 - Prob. 4.19PFSCh. 4 - Prob. 4.20PFSCh. 4 - Prob. 4.21PFSCh. 4 - Prob. 4.22PFSCh. 4 - Prob. 4.23PFSCh. 4 - Prob. 4.24PFSCh. 4 - Prob. 4.25PFSCh. 4 - Prob. 4.26PFS
Knowledge Booster
Similar questions
- Select an American Standard Channel shape for the following tensile loads: dead load = 54 kips, live load = 80 kips, and wind load = 75 kips. The connection will be with longitudinal welds. Use an estimated shear lag factor of U = 0.85. (In a practical design, once the member was selected and the connection designed, the value of U would be computed and the member design could be revised if necessary.) The length is 17.5 ft. Use Fy=50 ksi and Fu=65 ksi. a. Use LRFD. b. Use ASD.arrow_forwardA double-channel shape, 2C8 x 18.75 is used as a tension member. The channels are bolted to a ¾-inch gusset plate with % - inch diameter bolts. The tension member is A572 grade 50 steel and the gusset plate is A36. If LRFD is used, how much factored tensile load can be applied? Consider all limit states. →2" popoy |-|-|-|-|-| n оо- 0 0 0 0 x + = ³/8" 288×18.15arrow_forward5) Calculate P the allowable tensile load for the butt joint shown. Each A325-N high-strength bolt has a diameter of 0.9 inches. The plates are made of ASTM A36 steel. If the applied load is 200 kips, is this connection adequate? If not, what needs to be changed so that this connection can handle an applied load of 200 kips? P- ФФ P ! 12"x " P. P.arrow_forward
- (2) The connection shown below is bolted with 3/4 inch diameter, Group A slip-critical bolts in single shear. Assume that the bearing strength is adequate and use an elastic analysis to determine the maximum factored load that can be applied. 5.5" Column Flange o o O o o Gusset Plate 4sp. @3" O O 4" 30⁰ P₁ = ?arrow_forwardA C230x30 is connected to a 12.7mm gusset plate as shown. Grade A242 steel F, 345 MPa is used for the connected parts. The member is designed to resist a service dead load of 180 KN and service live load of 360 KN. Use LRFD NSCP 2015. Design the connection to be slip- Fy = 250 MPa 12.7 mm thick Gusset PL critical if A325X bolts are used. Draw a sketch of your design approximately to scale. What is the allowable load that the connection can carry? NSCP 2015. C230x30 Fy = 345 MPaarrow_forwardIf the 18 mm plate is connected to two cover plate of 10 mm on top and bottom, what is the capacity of the connection in double shear? Assume that the shear planes pass though the threaded portion. State the condition necessary for these strengths to be available. (Draw the connect first and calculate the capacity)arrow_forward
- A 3/4 in (thickness) X 5 in (height) steel plate is connected to another one through two bolts of nominal diameter 1/2 in in a zig-zag arrangement as shown. Determine the tensile strength capacity Pu of the connection. Review the three limit-states: (a) yielding in the gross area, (b) rup- ture in the overall net tensile area, and (c) block shear strength.arrow_forwardA992 steel is used for the tension member shown. The bolts are ¾ inch in diameter. The connection is to a ⅜ inch thick gusset plate. A. Determine the nominal strength based on the gross area. B. Determine the nominal strength based on the effective net area.arrow_forwardThe connection shown below uses 1-inch-diameter Group A bolts with the threads not in the shear plane. No slip is permitted. Both the tension member and the gusset plate are A36 steel. These bolts have not been added to distribute loads in the filler and two fillers are used. Use LRFD for solution. What is the design strength for block shear in kip? Express your answer in two decimal places. 1/2" thick Gusset Plate 3/8" thick 2" 3" 2" 2" 3" 3" 2"arrow_forward
- The connection shown below uses 1-inch-diameter Group A bolts with the threads not in the shear plane. No slip is permitted. Both the tension member and the gusset plate are A36 steel. These bolts have not been added to distribute loads in the filler and two fillers are used. Use LRFD for solution. What is the design strength for block shear in kip? Express your answer in two decimal places. 2" 3" 2" 1/2" thick Gusset Plate O 2" 3" 3" 2" 3/8" thick Parrow_forwardThe connection shown below uses 1-inch-diameter Group A bolts with the threads not in the shear plane. No slip is permitted. Both the tension member and the gusset plate are A36 steel. These bolts have not been added to distribute loads in the filler and two fillers are used. Use LRFD for solution. What is the design strength for tension on gross area in kip? Express your answer in two decimal places. 1/2" thick Gusset Plate 3/8" thick 2" 3" 2" 2" 3" 3" 2" P.arrow_forwardQuestion 3 Determine the capacity of plate as well as below connection based on Balts (4) in the below Following reactions :- 7 11 A325, $4 þ Bolts use! Use: AISC manual U Moment = 10 kip-67 2 kip (2) Shear (3) Axial 2 kip رب Ź Plate (A 36) 10 " x 10" x ≤ 11 8 HSS. их их nxuxt 4 H² 7arrow_forward