Principles of Instrumental Analysis
7th Edition
ISBN: 9781305577213
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 31, Problem 31.10QAP
Interpretation Introduction
Interpretation:
The cause of glass transition for
Concept introduction:
The glass transition is also known as glass−liquid transition an associated with the process in which glass is converted into a liquid state. Vitrification is a reverse process to glass−liquid transition.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
QUESTION 4
Answer the following questions based on the given table.
Compound
Chromophores
Wavelength (Ama)
Acetone
C=0
186 nm and 280 nm
190 nm
Butene
C=C
Fe(SCN)
aqueous solution of Ni²*
475 nm
400 nm
a) Based on the given chromophores, determine the types of electronic transitions which
occur for each of acetone and butene.
b) Provide the type of electronic transition which occur for the aqueous solution of Ni".
c) Iron(III) thiocyanate, Fe(SCN)* is an example of a charge-transfer complex. Outline the
steps of the electron transfer process in this complex.
What is the difference between an absorption spectrum and a standard curve?
What are the three most common ordered magnetic domain states for a crystal?
Chapter 31 Solutions
Principles of Instrumental Analysis
Knowledge Booster
Similar questions
- Briefly describe how a phase-contrast microscope work and the kind of image that itproduces. Give a specific use for this type of microscope.arrow_forwardWhen performing radioscopy is used: Required to answer. Single choice. the ability of the shortest rays to be well absorbed by the body excitation of atoms of matter and, as a consequence, luminescence chemical action of X-rays on photographic film The ability of the longest rays to pass through the body ionizing effect of X-raysarrow_forwardWhy do we need to prepare a standard curve before we can use Beer's Law to determine the concentration of a solution? O We don't have to create a standard curve so long as we choose the appropriate wavelength. Because the standard curve tells us the absorbance of our sample Because the standard curve is used to determine the extinction coefficient Because the standard curve indicates what wavelength to set the spectrophotometer toarrow_forward
- If the percent transmittance of a colored solution is found to be 35%, what amount of distilled water must be added to 100 ml of this solution in order to have a solution with a percent transmittance of 75%.arrow_forwardHow can we use the observed colors to determine quantities and identities of materials? I am highly confused by spectrometry.arrow_forwardWhat is scattering coefficient?arrow_forward
- why is a calibration curve likely to be linear over a wider range of concentrations at the wavelength of maximum absorption compared to a wavelength on a shoulder of the absorption curve?arrow_forward7. Suppose you are an employee of a plastics firm and you are assigned the task of identifying a polymer used by a competitor to make certain automotive parts. You prepare a film of the polymer and determine its IR spectrum, as shown below. What information can you deduce from the spectrum? Spectrum below plots transmittance (y-axis) vs. frequency in wavenumber (cm³¹) T прити JU 0 0 0 0 0 1000 3000 2000 1500 1000 500arrow_forwardIdentify and provide either an concise explanation of the concept signal-to-noise ratio (SNR), in the context of chemical analysis.arrow_forward
- Which parameter between "solvent polarity function" and dielectric constant show better correlation with the peak positions? (cyclohexane, dioxane, acetonitrile, ethanol, ethylene glycol)arrow_forwardMultiple peaks can be observed in the UV/Vis spectrum. Possible Falsearrow_forwardA particular liquid crystalline substance has the phasediagram shown in the figure. By analogy with the phasediagram for a nonliquid crystalline substance, identify thephase present in each area.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Physical ChemistryChemistryISBN:9781133958437Author:Ball, David W. (david Warren), BAER, TomasPublisher:Wadsworth Cengage Learning,Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningChemistry for Engineering StudentsChemistryISBN:9781285199023Author:Lawrence S. Brown, Tom HolmePublisher:Cengage Learning
Physical Chemistry
Chemistry
ISBN:9781133958437
Author:Ball, David W. (david Warren), BAER, Tomas
Publisher:Wadsworth Cengage Learning,
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Chemistry for Engineering Students
Chemistry
ISBN:9781285199023
Author:Lawrence S. Brown, Tom Holme
Publisher:Cengage Learning