![Principles of Instrumental Analysis](https://www.bartleby.com/isbn_cover_images/9781305577213/9781305577213_largeCoverImage.gif)
Principles of Instrumental Analysis
7th Edition
ISBN: 9781305577213
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 31, Problem 31.8QAP
Interpretation Introduction
Interpretation:
The chemical changes associated with endothermic and exothermic peaks in differential scanning calorimetry and differential thermal analysis are to be listed.
Concept introduction:
Determination properties of materials are done on the basis of change of temperature and it is known as thermal analysis. Many methods are there as example DSC or DTA etc.
Expert Solution & Answer
![Check Mark](/static/check-mark.png)
Trending nowThis is a popular solution!
![Blurred answer](/static/blurred-answer.jpg)
Students have asked these similar questions
The spectroscopic data in the table is generated with five solutions of known concentration.
Concentration (M)
0.0133
m=
0.0266
0.0532
0.106
0.213
Absorbance
0.1271
What is the intercept of the linear regression line?
0.08531
0.5388
1.069
Use a spreadsheet program, such as Microsoft Excel, to graph the data points and determine the equation of the best-fit line.
1.954
What is the slope of the linear regression line formed by these points?
M-1
Use the calibration curve or linear regression equation to determine the concentration of
FD&C blue dye No. 1 in Kool-aid.
Food Coloring is 0.026 M in FD&C blue dye No. 1
7.5 x 10 -5 M is 29 mL -> 1000 mL
What is the purpose of a calibration curve in analytical chemistry?
Chapter 31 Solutions
Principles of Instrumental Analysis
Knowledge Booster
Similar questions
- What photochemical reaction involving nitrogen oxides initiates the formation ofphotochemical smog?arrow_forwardDiscuss the different separation techniques. Sieving Paper Chromatography Evaporationarrow_forwardYou are interested to know the Q10 value for mean heart rate (# of beats/10 sec) for a species of crab for the temperature interval of 25°C - 35°C. To find this value, you collect data for these six temperatures and calculate mean heart rate (# of beats/10 sec) for each temperature. Here is the data: 10°C 15°C 20°C 25°C 30°C 35°C Mean Heart Rate (# 23.67 23.89 24.33 27 35.89 37.78 beats/10 sec) What is the Q1o value for heart rate (# of beats/10 seconds) for the temperature interval of 25°C - 35°C? Round your answer to two decimal places.arrow_forward
- Construct a calibration curve based on the following data: Concentration Fe 0.100 0.500 2.00 4.00 7.00 (ppm) Absorbance 0.0122 0.0608 0.2322 0.455 0.5858 Use LINEST to find the slope and intercept and their uncertainties. Enter your answer as a number with no units to three significant figures. 0.085 0.037 b m 0.100 0.500 Sm Sb r2 0.958 0.037 Syarrow_forwardWhich one is the most common method used for the purification of liquid mixtures? Filtration Chromatography Evaporation Distillationarrow_forwarduse analytical separation and analyses to outline analytical separation method protocols that can be employed to recover extremely high deposit of heavy metals and particulate matter in the river making wholesome for drinking in illegal mining communities .arrow_forward
- You determine the Mg concentration of a water sample using atomic absorption spectroscopy (AAS). The sample is first diluted: 4.00 mL of the water sample is diluted to a final volume of 25.0 mL. The AAS reading for the diluted sample is 1.755 ppm. What was the Mg concentration of the original water sample, in ppm? (Enter the numerical value without units.)arrow_forwardwhat is spectrophotometry? how is it related to Beer's Law?arrow_forwardThe proton NMR spectrum of a compound, C3H6Cl2, has a pentet at d 2.19 and a triplet at & 3.72 with a 1:2 integration ratio, respectively. Which compound below best matches the data? A) CH₂CH₂CHC1₂ B) CICH₂CH₂CH₂C1 C) CH3CHCH₂C1 Cl C1 D) CH3CCH3 C1arrow_forward
- What are the differences between systematic and random errors and how do they effect accuracy and precision? In what circumstances would you use standard addition (versus a normal calibration curve) to determine the amount of an analyte in a sample? A urine sample, containing analyte Z is analysed by the standard addition method where 5 mL of the original sample was mixed with increasing amounts of a Z standard and each solution diluted to a volume of 50 mL prior to analysis. A plot of the final concentration of the standard in each of the 50 mL samples (x axis) versus The measured signal from the analysis of each 50 mL sample (on y axis) produced a straight line with the general equation: y = 44.72x + 4.06 what was the final concentration of Z in the 50 mL standard addition sample? what was the initial concentration of Z in the original urine sample?arrow_forwardWhat is the difference between a primary and a secondary standard? Give an example of each.arrow_forwardColor is an important indicator of temperature and is used to adjust a lab Bunsen burner. Match the color of the flame with the temperature. Cool temperature Medium temperature Hot temperature Answer Bank blue flame with a tall blue cone blue with a short, bright blue flame orange-colored flame that moves and flickersarrow_forward